© Böning Ship Automation. Image courtesy of Böning.

AHD 514 S — Böning Diesel Engine Safety Unit

The Böning AHD 514 S provides a diesel-engine safety channel independent of the AHD 514 A alarm system, with separate processing of safety shutdown criteria and emergency-stop inputs.

Original Product OEM Quality

Availability

TH 36 Marine StockAvailability on request
SKU: TH36-LP-001695
Category: ,
Brands:

Description

Overview

The Böning AHD 514 S provides a diesel-engine safety channel independent of the AHD 514 A alarm system, with separate processing of safety shutdown criteria and emergency-stop inputs.

Operation and integration

Separate 24 V DC +30%/−25% supplies serve the safety and emergency-stop circuits. Emergency-stop activation is passed directly to its output independently of the safety function. Redundant safety sensors are acquired separately from the alarm system.

Key features

  • Two independent wire-break-monitored emergency inputs
  • Five wire-break-monitored stop-criterion inputs
  • Five function inputs for acknowledgement, reset, override and override testing
  • One isolated speed input
  • Four potential-free 6 A relays
  • Two 8 A protected transistor outputs for safety-system engine-stop magnets or air dampers
  • One separate 8 A protected emergency-stop transistor output
  • One 4–20 mA speed-display output
  • CAN connection to AHD 514 A
  • One optocoupler serial output
  • IP20 rail-mount housing and pluggable terminals
  • Engine-series-specific adaptation

Approvals

Manufacturer-listed approvals: ABS, BV, CRS, DNV, LR, RS.

Additional information

Manufacturer product family

Diesel Engine Monitoring and Safety Systems

Dimensions W x H x D

148 mm x 128 mm x 77 mm

Weight

Appr. 0.50 kg

Operating Temperature

-30°C … +70°C

Storage Temperature

-50°C … +85°C

Protection Class

IP 20

Power Supply

Safety system: 24 V DC (+30% / -25%) Emergency stop system: 24 V DC (+30% / -25%)

Power/Current Consumption

Max. 98 mA (24 V DC)

Inputs

2 x binary, wire break monitored (emergency stop)
5 x binary, wire break monitored (stop criteria)
5 x binary (control inputs)
1 x engine speed input, galvanically isolated

Outputs

4 x relay 6 A (32 V DC), potential-free (for horn, collective alarm, etc.)
2 x transistor, 8 A (32 V DC), wire break monitored, short-circuit-proof (solenoid / operating solenoid, flapper valves; stop by safety system)
1 x transistor, 8 A (32 V DC), wire break monitored, short-circuit-proof (stop by emergency stop system)
1 x power output 4-20 mA (for external engine speed display)
10 x LED indicators

Ports

1 x CAN bus (communication)
1 x serial output (optocoupler)

Installation Type

Profile module housing, installation on DIN Rail TS32 / TS35

Approvals

ABS, BV, CRS, DNV, LR, RS

Item Number

12973

Downloads