© Böning Ship Automation. Image courtesy of Böning.

AHD 504 A — Böning Diesel Engine Start-Stop Monitor

The Böning AHD504 A starts, stops and monitors diesel engines with automatic overspeed shutdown and engine-series-specific configuration.

Original Product OEM Quality

Availability

TH 36 Marine StockAvailability on request
SKU: TH36-LP-001804
Category: ,
Brands:

Description

Overview

The Böning AHD504 A starts, stops and monitors diesel engines with automatic overspeed shutdown and engine-series-specific configuration.

Operation and integration

Its inputs comprise one isolated speed channel,11 configurable analogue channels, three wire-break-monitored binary channels and six control inputs for functions such as remote start/stop, acknowledgement and overspeed testing.

Key features

  • Four potential-free 3 A relays
  • One 8 A wire-break-monitored, short-circuit-protected transistor output
  • One 32 V/25 mA transistor output
  • 24 V DC +30%/−25%
  • Two CAN interfaces with optional external J1939 connection
  • RS232 9-pin Sub-D for diagnostics/firmware
  • One optocoupler serial input and one serial output
  • Pluggable strips
  • IP20 standard-rail housing

Additional information

Manufacturer product family

Spare Parts & Refit

Dimensions W x H x D

173 mm x 128 mm x 55 mm (height including plug connector 65 mm)

Weight

Appr. 0.5 kg

Operating Temperature

-25°C … +70°C

Storage Temperature

-50°C … +85°C

Protection Class

IP 20

Power Supply

24 V DC (+30% / -25%)

Current Consumption

Max. 100 mA (24 V DC)

Inputs

20 inputs, relative to device’s ground (GND): – 9 x analog (selection of 4–20 mA / PT1000/bin with jumper) – 2 x analog (selection of NiCrNi / 0-32 V with jumper) – 3 x binary (contact / Bedia with wire break monitoring) – 6 x binary (control inputs)
1 x engine speed input (pickup, galvanically isolated)

Outputs

1 x transistor 8 A (32 VDC), wire break monitored, short-circuit- proof (for solenoid or operation solenoid)
4 x relay 3 A (32 V DC, potential-free)
1 x transistor (32 V / 25 mA)
2 x LED indicators (power, fault)

Ports

2 x CAN bus (communication/optional external engine bus J1939)
1 x RS232 (9-pin Sub-D, diagnosis, firmware update)
1 x serial input (optocoupler)
1 x serial output (optocoupler)

Installation Type

Profile module housing, installation on DIN rail TS32 / TS35

Approvals

DNV, LR, RS

Item Number

AHD 504 A: 14639
AHD 504 A COM: 14744

Downloads