© Böning Ship Automation. Image courtesy of Böning.

AHD-UIC — Böning Modbus to CAN Gateway

The Böning AHD-UIC converts third-party Modbus RTU information into the Böning SAS CAN protocol for ship-system displays and panel PCs.

Original Product OEM Quality

Availability

TH 36 Marine StockAvailability on request
SKU: TH36-LP-001813
Category: ,
Brands:

Description

Overview

The Böning AHD-UIC converts third-party Modbus RTU information into the Böning SAS CAN protocol for ship-system displays and panel PCs.

Operation and integration

A project-specific configuration operates as bus master at up to 38400 baud and cyclically processes up to 100 Modbus packets. A master/slave device pair can provide a redundant arrangement.

Key features

  • CAN and LAN interfaces
  • Isolated Modbus connections
  • Versions with two RS485, two RS422 or one of each
  • DIN-rail housing for consoles or control boxes

Approvals

Manufacturer-listed approvals: ABS, CRS, DNV, LR, RINA.

Additional information

Manufacturer product family

Spare Parts & Refit

Power supply

18…32 V DC

Current consumption

Ca. 400 mA (24 V DC)

Operating temperature

-25°C…70°C

Storage temperature

-30°C…85°C

Weight

Ca. 2 kg

Degree of protection

IP 20

Dimensions W x H x D

135 mm x 130 mm x 55 mm

Input interfaces

2 x RS485 – Modbus RTU

Output

1 x CAN

Assembly

On rail TS 32 and TS 35

Approvals

ABS, CRS, DNV, LR, RINA

Required distance to compass

Standard magnetic compass: 0.50 m
Steering magnetic compass: 0.40 m

Downloads