Description
Overview
The Böning AHD 414 starts, stops and monitors diesel engines, with configuration for different manufacturer series.
Operation and integration
Integrated ignition and programmable overspeed monitoring work with 10 binary status/alarm inputs. Front keys acknowledge visual/acoustic alarms and provide reset, early stop-signal termination and lamp testing.
Key features
- Five engine/alarm relays rated 2 A continuous
- Two solenoid relays rated 20 A inrush/10 A continuous
- 24 V DC +30%/−25% or 12 V DC supply
- Approximately 0.15 A at 24 V
- Serial data output
- 22-pole pluggable terminals
- 144 × 144 mm front,53 mm depth
- IP54 front with cover
- Console, panel or box installation